Detroit 60 series starting problems.

Still no start. Sprayed starter fluid in the air intake and it starts right up and runs as long as you keep putting starter fluid in. Seems like something has the fuel shut off. This is a 2005 freight liner with a 14 liter engine, Detroit 60 series. When you turn the key on all the instrument gauges sweep to the right and back to the left.

Detroit 60 series starting problems. Things To Know About Detroit 60 series starting problems.

1. Place the red lead of a voltmeter to the solenoid "BAT" terminal. 2. Place the black voltmeter lead to the starter ground terminal, 3. Engage the starter switch. 4. View the voltage reading on the meter. If the voltage is less than specification while cranking the engine, replacement is necessary;Series 60 Aerated Fuel Misfiring Cylinder. To determine if aerated fuel is causing the cylinder to misfire, perform the following steps: ‪. Disconnect the fuel line return hose from the fitting located at the fuel tank. Place the opened end of fuel line into a suitable container. Start the engine. Visually check to see if air bubbles are ...Series 60 DDEC IV white smoke and backfiring. I'm working on a HK model series 60 engine and it has a strange problem. At idle if you snap the throttle it misses and starts blowing white smoke. It runs fine going down the road till you get to last 2 gears and it will smoke and backfire when the throttle is released to shift gears.Detroit 60 series hard start in morning Discussion in 'Freightliner Forum' started by rsinghpal, Aug 23, 2023. Aug 23 ... Having a strange problem with my truck and I was hoping someone here would have a clue based on my particular symptoms. I have a 2005 Freightliner with a 14l EGR Detroit 60 Series. For the last several weeks if I turn the ...

4. Start and bring engine up to operating temperature (over 140°F/60°C). 5. Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313-592-5800.

Section 3.8.2. Removal of Oil Cooler. Remove the oil cooler core and housing as follows:‪. Drain the cooling system by opening the drain cocks at the right rear of the cylinder block, and in the bottom of the water pump housing. Disconnect the hose from the water pump at the lower neck of the oil cooler housing.Soluble Oils. Soluble oil additives are not approved for use in the Detroit Diesel Series 60 engine cooling systems. A small amount of oil adversely affects heat transfer. A 1.25% concentration of soluble oil increases the fire deck temperature 6%. A 2.50% concentration increases the fire deck temperature 15%.‪.

SHUTDOWN. Now do this, in the programming section and look under 'protection'. click on the aux box and set it to either 1-shutdown, 2 ramp down, or 3 warning. This way you will get a rampdown in power then the shutdown, OR just warning light and NO shutdown. Programming for a shutdown will require a recycle of the key.4. Start and bring engine up to operating temperature (over 140°F/60°C). 5. Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313-592-5800.Series 60 - Low Power - INCORRECT CAMSHAFT TIMING. Check the camshaft timing; if the dial indicator reading is within 0.262 - 0.284 in. (6.655 - 7.214 mm), no further troubleshooting is required. If the dial indicator reading is not within 0.262 - 0.284 in. (6.655 - 7.214 mm), check engine timing; refer to section 12.11.1.Series 60 - Section 3.8 Oil Cooler (1991 and Later Engines) Series 60 - Section 3.4 Oil Pressure Relief Valve; Series 60 - Section 3.5 Oil Filter; Series 60 - Section 3.6 Oil Filter Adaptor; Series 60 - Section 3.2 Oil Pump; Series 60 - Section 3.3 Oil Pressure Regulator Valve; Series 60 - Section 3.1 Overview of Lubricating System

This TRS is called crank sensor on a car and I'm sure all motors with a ECM on cars, trucks and probably even late model motorcycles will have a crank sensor...

Refer to "9.2.2 Removal of Alternator" . Remove the drive belt auto tensioner assembly from the mounting plate on the gear case cover. Remove the mounting plate from the gear case cover. Drill a 0.425 in. diameter hole on the left side of the mounting plate and thread with a 1/4 in. NPTF - 4FF tap.

The diagnostic trouble codes are generated in the ECM when a condition exists that prevents the engine from operating at peak efficiency. The DTC will help guide the technician to the condition . The technician will require a knowledge of the system and proper tools to diagnose the components.‪. Three primary codes exist; they are Component ...Read all about Detroit Metropolitan Wayne County Airport (DTW) here as TPG brings you all related news, deals, reviews and more. The Detroit Metropolitan Wayne County Airport is th...My bad on the spec. Detroit Series 60 rail specifications is 58-72 PSI. The closer to 70 PSI, the better. Almost all of my 60 series injector failures where the injector not opening, not saying it's the rule just my experience . ... Working on a 1996 international 8100 with M11 Cummins engine. I am having a problem with starting. I am having an ...Series 60 – STARTING DIFFICULTY – ENGINE ROTATES – CRANK NO START. The engine cranks but does not start. Check for the following: Low Fuel Level. …My detroit 60s 12.7 engine lost power. When I start driving truck drives normally and has power for first 5-20min then in a second I have no power. It takes like a minute to go from 0 to 60 and no big difference if empty or loaded. I can hear a turbo but the sound is weak even at higher rpms.

The Detroit Diesel Diagnostic Link ® (DDDL) is a sophisticated PC software package that requests and receives engine data and diagnostic codes. The Detroit Diesel Diagnostic Link ® DDDL supports DDEC V and the Series 60 2004 engine. The DDDL functions are: ‪. Read and display current calibration for an ECU. Create a calibration for the ECU ...series 60 – excessive crankcase pressure – defective air compressor To determine if a defective air compressor is causing excessive crankcase pressure, perform the following: 1.Perform a crankcase pressure test, refer to appropriate service manual, preventive maintenance chapter and record the test results.Sep 15, 2021 · 1994 Detroit 60 Series 12.7 jake brake problem. Discussion in 'Freightliner Forum' started by davis28905, Sep 15, 2021. Sep 15, 2021 #1. davis28905 Bobtail ... Series 60 – Section 4.8 Radiator; Series 60 – Section 4.5 Coolant Pressure Control Cap; Series 60 – Section 4.6 Engine Cooling Fan; Series 60 – Section 4.4 Thermostat; Series 60 – Section 4.2 Water Pump (Gear-Case Mounted – 1991 and Later) (GCM) Series 60 – Section 4.3 Water Pump (Front Mounted) (Fm) Series 60 – Section …14. 8. Jun 12, 2015. 0. I have a 2004 Series 60 Detroit that has a serious problem with cranking and cranking and cranking until it juuuusssst finally starts. I have heard that check valves can be an issue on the Detroit so I replaced the check valve behind the engine and also the one that is inline on the right side of the filter housing.

Figure 1. Viscous Vibration Damper Mounting with Crankshaft Pulley or Crankshaft Pulley and Hub Assembly with Spindle. Prior to April 1993, 11.1 liter engines with less than 320 hp (238 kW) were equipped with a 313.4 mm (12.34 in.) damper and 11.1 liter engines with 320 hp (238 kW) or more were equipped with a 342.9 mm (13.5 in.) …

Section 14.1Maintenance Overview. The lubrication and preventive maintenance schedule is intended as a guide for establishing a preventive maintenance schedule. The suggestions and recommendations for preventive maintenance should be followed as closely as possible to obtain long life and best performance from the Series 60 engine.Information for Series 60 Engines,” available from authorized Detroit Diesel service outlets. Keep this Operator's Guide with the engine installation at all times. It contains important operating, maintenance, and safety instructions. Trademark Information DDC®, Detroit Diesel®, DDEC®, Series 60®, Optimized Idle®, Diagnostic Link ...Series 60 – Section 1.21 Piston and Connecting Rod Assembly; Series 60 – Section 1.17 Ring Gear; Series 60 – Section 1.18 Flywheel Housing; Series 60 – Section 1.14 Crankshaft Vibration Damper; Series 60 – Section 1.15 Crankshaft Pulley; Series 60 – Section 1.16 Flywheel; Series 60 – Section 1.13 Gear Case Exhaust Gas ...Series 60 Improper Engine Coolant Level To determine if improper engine coolant level is causing high engine coolant temperature, perform the following: ‪ Visually inspect the… Posted in TroubleshootingPossible misfire on a Detroit series 60. I am having some trouble figuring out what is wrong with one of our Freightliners, the engine is a D60, on start up it is running rough and loud, the best way to describe it is like a gasoline engine with a misfire. The driver noticed loss of power and it is blowing white smoke out of the stack.Reinstall the SFT Sensor, refer to the Series 60 Service manual (6SE2007), fuel system chapter. Analyze the measured fuel pressure readings. If the fuel pressure is within specification listed in Table "Fuel Pressure (DDEC VI with Regulator)" , check for high fuel temperature return; refer to "12.5 High Fuel Temperature Return" .

To determine if a faulty fuel injector is causing the cylinder to misfire, perform the following steps: ‪. Install DDL adaptor to the data cable and plug the adaptor into the DDL connector in the vehicle; refer to OEM guidelines. Start the engine. >From the DDEC III/IV Select Menu, scroll to select ENGINE and press the ENTER key.

Series 60 DDEC V Troubleshooting - Section 19.6 Explanation of Abbreviations and Terms. ... Detroit Diesel Corporation‪ ... the self diagnostic system has detected a problem. If the problem goes away, the light will go out, but a trouble code will be stored in the ECM/ECU as an inactive code. † As a light bulb check and system check, the ...

Fuel Knock Problems. If you haven't modified the engine, then odds are that you've got some sort of fuel leakage in the cylinder. This fuel could come from a leaking injector, but it could just as well be an internal oil leak. The Series 60 is more than capable of using its oil for fuel, so oil leaking into the cylinder through bad seals or ...The truck is a 2008 Freightliner Colombia with a Detroit 60 series with 630k miles. The problem I am having with the truck is: 1. wont perform auto regen. 2: will not finish a park regen. I took the truck to a well known independent Detroit mechanic which was referred by couple of drivers in the area.The Series 60 debuted in 1987 for the North American class-8 market. Much of its development happened as a collaboration between Detroit Diesel and John Deere, for example, the ring system, the cylinder heads, and most notably the electronic engine control. In the end, the two companies kept manufacturing separately, but their efforts produced ...Learn how to fix the ECM problem on your Detroit 60 Series engine with this semi mechanical tutorial video.InvestorPlace - Stock Market News, Stock Advice & Trading Tips Today we will discuss three car stocks to buy as the North American Internation... InvestorPlace - Stock Market N...To determine if aerated fuel is causing starting difficulty, perform the following steps: ‪. Disconnect the fuel line return hose from the fitting located at the fuel tank; refer to OEM guidelines. Place the opened end of the fuel line into a suitable container. Start the engine. Run the engine at 1000 r/min.Service Manual, 6SE483, January 2004 Abstract This manual provides instruction for servicing on-highway, construction and industrial, generator set, and marine applications of the Detroit Diesel Series 60 Diesel and Natural Gas-fueled engines. Specifically a basic… Detroit Diesel Series 60 Main Bearing & Thrust… Another day, another part.I decided to take my 73-year-old mother on a quick one-night getaway to Detroit, using one of my Delta Air Lines companion certificates, as a way to create new memories after a yea...Hi I have 2006 freightliner Detroit 60 series 14l with egr losing power and white smoke when engine reaches normal temperature the shop has already replaced 3 pods 2 turbos ,egr,ecm,engine harness,vpod harness the problem has still not been found after all these parts I still get load of white smoke when engine reaches normal temperature.Alright, this either could be a problem with the Jake brakes or a EGR solenoid/wiring problem. A problem in the EGR system can definatly cause power loss under a load. Your truck being a 2002, check to see if you have an EGR valve. It would be located under the turbo near the block bolted onto the EGR cooler.When removal of the crankshaft becomes necessary, first remove the transmission, then proceed as follows:‪. Steam clean the exterior of the engine. Refer to "1.1.3 Cleaning the Cylinder Block" . Drain the cooling system. Refer to "14.6.4 Cooling System" . Drain the lubricating oil. Refer to "14.6.1 Lubricating Oil" .wayne : lets start with, governor, black rubber cap on it, remove that, now you will see stud with 2 7/16 nuts, loose the nuts and screw the stud inward , count you turns, then back it off same turns, then 1 extra 1/2 turn, compressor should kick in, you will here it. wayne : if not , then that part is bad. Wayne.

Series 60 Low Cranking Speed. To determine if low cranking speed is causing starting difficulty, perform the following steps: ‪. Install a tachometer to the engine and record engine revolution while cranking the engine; refer to OEM for guidelines. If the cranking speed is greater than 100 r/min, check the fuel supply valve;Figure 1. Viscous Vibration Damper Mounting with Crankshaft Pulley or Crankshaft Pulley and Hub Assembly with Spindle. Prior to April 1993, 11.1 liter engines with less than 320 hp (238 kW) were equipped with a 313.4 mm (12.34 in.) damper and 11.1 liter engines with 320 hp (238 kW) or more were equipped with a 342.9 mm (13.5 in.) …Series 60 - MISFIRING CYLINDER - FAULTY FUEL INJECTOR. To determine if a faulty fuel injector is causing the cylinder to misfire, perform the following steps: 1. Connect to DDDL 7.0. 2. Start the engine. 3. From the Select Menu, scroll to select ENGINE and press the ENTER key. 4.Instagram:https://instagram. affidavit for i 751how old is gary from dish nationbowling green ky motorcycle dealersemission test elk grove village Series 60 Improper Engine Coolant Level To determine if improper engine coolant level is causing high engine coolant temperature, perform the following: ‪ Visually inspect the… Posted in Troubleshooting allicia beamplant city premiere lux 8 and pizza pub about Series 60 - DDEC I; Series 40E Troubleshooting - Section 3.1 Injection Control Pressure System Operation; Series 60 - DDEC® V ELECTRONIC CONTROL UNIT - SERIES 60 2004; Series 60 - Fuel Lines; Series 60 - Section 2.49 Low Pressure Fuel Regulator for the Series 60G Engine; Series 60 - Section 2.50 Fuel Mixer for the Series 60G Low ... quiktrip memphis Detects water in the fuel filter that alerts the owner/driver that the fuel filter needs to be dried out.‪. Table 2. Function of Factory-installed Sensors. See Figure "Sensor Location for the DOC and DPF" for the location of the sensors for the DOC and DPF.‪. Figure 1. Sensor Location for the DOC and DPF. Section 17.7.2.Only from Detroit. The most successful Detroit Diesel engine ever produced, the Series 60 was also the first engine in the world to fully utilize electronic engine controls. With more than 1.2 million units sold since 1987, the Series 60 was the most widely used heavy-duty truck engine in North America by 1992.15 Jan 2024 ... Comments13 ; Cold Start on Detroit diesel 60 series compilation. Life with Big E · 9.3K views ; Kenworth W900 C15 Cat Main Bearing Issues · New ....